EV 0
¾“ ,1 ½“, 2“, 2 ½“
|
EV 1
¾“ ,1 ½“, 2“, 2 ½“
|
|
|
|
|
|
|
|
Up:
Up to 0.16 m/s (32 fpm). 1 Up Speed. Up Start is smooth and adjustable. Up Stop is by de-energising the pump-motor.
|
Up:
Up to 0.16 m/s (32 fpm). 1 Up Speed. Up to 0.4 m/s (80 fpm) by over travelling and levelling back down. Up Start is smooth and adjustable. Up Stop is smooth and exact through valve operation whereby the pump must run approx. ½ sec. longer through a time relay.
|
Up:
Up to 1.0 m/s (200 fpm). 1 Full Speed and 1 Levelling Speed. Up Start and Slow Down are smooth and adjustable. Up Levelling speed is adjustable. Up Stop is by de-energising the pump-motor. |
Up:
Up to 1.0 m/s (200 fpm). 1 Full Speed and 1 Levelling Speed. All 'up' functions are smooth and adjustable. Up Levelling speed is adjustable. Up Stop is smooth and exact through valve operation whereby
the pump must run approx. ½ sec. longer through a time relay. |
Down:
Up to 1.0 m/s (200 fpm). 1 Full Speed and 1 Levelling Speed. All down functions are smooth and adjustable. |
Down:
Up to 1.0 m/s (200 fpm). 1 Full Speed and 1 Levelling Speed. All down functions are smooth and adjustable. |
Down:
Up to 1.0 m/s (200 fpm). 1 Full Speed and 1 Levelling Speed. All down functions are smooth and adjustable. |
Down:
Up to 1.0 m/s (200 fpm). 1 Full Speed and 1 Levelling Speed. All down functions are smooth and adjustable. |
|
| Technical Data: |
|
¾“ EV |
1 ½“ und 2“ EV |
2 ½“ EV |
|
|
|
|
|
| Flow Range: |
l/min |
10 - 125 (2-33 USgpm) |
30 - 800 (8-208 USgpm) |
500 - 1530 (130-400 USgpm) |
| Pressure Range: |
bar |
5 - 100 (74-1500 psi) |
3 - 100 (44-1500 psi) |
3 - 68 (44-1000 psi) |
| Press. Range CSA: |
bar |
5 - 100 (74-1500 psi) |
3 - 70 (44-1030 psi) |
3 - 47 (44-690 psi) |
| Burst Pressure Z: |
bar |
575 (8450 psi) |
505 (7420 psi) |
340 (5000 psi) |
| Pressure Drop P–Z: |
bar |
6 (88 psi) at 125 lpm |
4 (58 psi) at 800 lpm |
4 (58 psi) at 1530 lpm |
| Gewicht: |
kg |
5 (11 lbs) |
10 (22 lbs) |
14 (31 lbs) |
|
| Oil Viscosity: |
25-60 mm²/sec. at 40°C (15-35 cSt. at 120°F) |
| Solenoids AC: |
24 V/1.8 A, 42 V/1.0 A, 110 V/0.43 A, 230 V/0.18 A, 50/60Hz |
| Solenoids DC: |
12 V/2.0 A, 24 V/1.1 A, 42 V/0.5 A, 48 V/0.6 A, 80 V/0.3 A, 110 V/0.25 A, 196 V/0.14 A. |
| Max. Oil Temperature: |
70°C (158°F) |
| Insulation Class, AC and DC: |
IP 68 |
|
|
The BLAIN EV 100 program includes the widest range of options offered to the elevator industry for high performance passenger elevators. Easy to install, EV 100‘s are smooth, reliable and precise in operation throughout extreme load and
temperature variations.
Description
Available port sizes are 3/4“, 1 ½“, 2“ and 2 ½“ pipe threads, depending the flow. EV 100‘s start on less than minimum load and can be used for across the line or wye-delta starting. According to customers‘ information, valves are factory adjusted, ready for operation and very simple to readjust if so desired. The patented up levelling system combined with compensated pilot control ensure stability of elevator operation and accuracy of stopping independent of wide temperature variations. EV 100 valves include the following features essential to efficient installation and trouble free service:
| Simple Responsive Adjustment |
Self Cleaning Pilot Line Filters |
| Temperature and Pressure Compensation |
Self Cleaning Main Line Filter (Z-T) |
| Solenoid Connecting Cables |
Built-in Turbulence Suppressors |
| Pressure Gauge and Shut Off Cock |
70 HRC Rockwell Hardened Bore Surfaces |
| Self Closing Manual Lowering |
100% Continuous Duty Solenoids |
|
|
USA Patent No. 4,601,366 Pats & Pats Pend: France, Germany, Italy, Japan, Switzerland & U.K.
|
|
|